Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28.447
Filter
1.
J Cardiothorac Surg ; 19(1): 199, 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38600502

ABSTRACT

BACKGROUND: Total endovascular technique with fenestrated endovascular graft might be hampered for the late dilatation of proximal landing zone, which may cause endografts migration. We describe a successful urgent hybrid procedure for extent III thoracoabdominal aortic aneurysm with aortic intramural hematoma. CASE PRESENTATION: A 55-year-old female with thoracoabdominal aortic aneurysm was considered at high surgical risk and unfit for open repair due to multiple comorbidities. Therefore, a hybrid procedure of surgeon-modified fenestrated endovascular graft combined with thoracoscope-assisted Transaortic epicardial fixation of endograft was finally chosen and performed in the endovascular operating room. A 3-port technique was performed through a left video-assisted thoracoscopic approach. After the first tampering stent-graft was deployed, a double-needle suture was penetrated both the aortic wall and stent-graft to fixate it in the proximal descending aorta. Then the second endograft, which had been fenestrated on table, was introduced and oriented extracorporeally by rotating superior mesenteric artery and left renal artery fenestration radiopaque markers and deployed with perfect apposition between the fenestrations and target visceral artery. Each vessel was sequentially stented using Viabahn self-expandable stent to finish target vessel stenting. An Ankura cuff stent was deployed in the distal abdominal aortic artery. CONCLUSION: Surgeon-modified fenestrated endovascular graft combined with thoracoscope-assisted fixation may be an innovative and viable alternative for selected high-risk patients with extent III thoracoabdominal aortic aneurysm. A longer follow-up is needed to ascertain the success of this approach.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Aneurysm, Thoracic , Aortic Aneurysm, Thoracoabdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Surgeons , Female , Humans , Middle Aged , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/methods , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/etiology , Thoracoscopes , Treatment Outcome , Stents , Endovascular Procedures/methods , Prosthesis Design , Aortic Aneurysm, Abdominal/surgery
2.
Catheter Cardiovasc Interv ; 103(6): 982-994, 2024 May.
Article in English | MEDLINE | ID: mdl-38584518

ABSTRACT

Endovascular aortic repair is an emerging novel intervention for the management of abdominal aortic aneurysms. It is crucial to compare the effectiveness of different access sites, such as transfemoral access (TFA) and upper extremity access (UEA). An electronic literature search was conducted using PubMed, EMBASE, and Google Scholar databases. The primary endpoint was the incidence of stroke/transient ischemic attack (TIA), while the secondary endpoints included technical success, access-site complications, mortality, myocardial infarction (MI), spinal cord ischemia, among others. Forest plots were constructed for the pooled analysis of data using the random-effects model in Review Manager, version 5.4. Statistical significance was set at p < 0.05. Our findings in 9403 study participants (6228 in the TFA group and 3175 in the UEA group) indicate that TFA is associated with a lower risk of stroke/TIA [RR: 0.55; 95% CI: 0.40-0.75; p = 0.0002], MI [RR: 0.51; 95% CI: 0.38-0.69; p < 0.0001], spinal cord ischemia [RR: 0.41; 95% CI: 0.32-0.53, p < 0.00001], and shortens fluoroscopy time [SMD: -0.62; 95% CI: -1.00 to -0.24; p = 0.001]. Moreover, TFA required less contrast agent [SMD: -0.33; 95% CI: -0.61 to -0.06; p = 0.02], contributing to its appeal. However, no significant differences emerged in technical success [p = 0.23], 30-day mortality [p = 0.48], ICU stay duration [p = 0.09], or overall hospital stay length [p = 0.22]. Patients with TFA had a lower risk of stroke, MI, and spinal cord ischemia, shorter fluoroscopy time, and lower use of contrast agents. Future large-scale randomized controlled trials are warranted to confirm and strengthen these findings.


Subject(s)
Blood Vessel Prosthesis Implantation , Catheterization, Peripheral , Endovascular Procedures , Femoral Artery , Humans , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Femoral Artery/diagnostic imaging , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/mortality , Treatment Outcome , Risk Factors , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Female , Male , Risk Assessment , Upper Extremity/blood supply , Aged , Punctures , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/mortality , Pilot Projects , Time Factors , Stroke/etiology , Stroke/mortality , Stroke/prevention & control , Middle Aged , Aged, 80 and over , Endovascular Aneurysm Repair
3.
J Cardiothorac Surg ; 19(1): 189, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38589942

ABSTRACT

BACKGROUND: This study aimed to elucidate the methodology and assess the efficacy of the aortic arch inclusion technique using an artificial blood vessel in managing acute type A aortic dissection (ATAAD). METHODS: We conducted a retrospective review of 18 patients (11 males and 7 females, average age: 56.2 ± 8.6 years) diagnosed with ATAAD who underwent total aortic arch replacement (TAAR) using an artificial vascular "inclusion" between June 2020 and October 2022. During the operation, deep hypothermic circulatory arrest (DHCA) and selective antegrade cerebral perfusion (ACP) of the right axillary artery were employed for brain protection. The 'inclusion' total aortic arch replacement and stented elephant trunk (SET) surgery were performed. RESULTS: Four patients underwent the Bentall procedure during the study, with one additional patient requiring coronary artery bypass grafting (CABG) due to significant involvement of the right coronary orifice. Three patients died during postoperative hospitalization. Other notable complications included two cases of postoperative renal failure necessitating continuous renal replacement therapy (CRRT), one case of postoperative double lower limb paraplegia, and one case of cerebral infarction resulting in unilateral impairment of the left upper limb. Eleven patients underwent computed tomography angiography (CTA) examinations of the aorta three months to one-year post-operation. The CTA results revealed thrombosis in the false lumen surrounding the aortic arch stent in seven patients and complete thrombosis of the false lumen around the descending aortic stent in eight patients. One patient had partial thrombosis of the false lumen around the descending aortic stent, and another patient's false lumen in the thoracic and abdominal aorta completely resolved after one year of follow-up. CONCLUSIONS: Incorporating vascular graft in aortic arch replacement simplifies the procedure and yields promising short-term outcomes. It achieves the aim of total arch replacement using a four-branch prosthetic graft. However, extensive sampling and thorough, prolonged follow-up observations are essential to fully evaluate the long-term results.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Substitutes , Blood Vessel Prosthesis Implantation , Thrombosis , Male , Female , Humans , Middle Aged , Aorta, Thoracic/surgery , Blood Vessel Prosthesis Implantation/methods , Aortic Dissection/surgery , Stents , Aorta, Abdominal/surgery , Paraplegia , Thrombosis/surgery , Aortic Aneurysm, Thoracic/surgery , Treatment Outcome
4.
Sci Rep ; 14(1): 8924, 2024 04 18.
Article in English | MEDLINE | ID: mdl-38637613

ABSTRACT

Accurate measurement of abdominal aortic aneurysm is essential for selecting suitable stent-grafts to avoid complications of endovascular aneurysm repair. However, the conventional image-based measurements are inaccurate and time-consuming. We introduce the automated workflow including semantic segmentation with active learning (AL) and measurement using an application programming interface of computer-aided design. 300 patients underwent CT scans, and semantic segmentation for aorta, thrombus, calcification, and vessels was performed in 60-300 cases with AL across five stages using UNETR, SwinUNETR, and nnU-Net consisted of 2D, 3D U-Net, 2D-3D U-Net ensemble, and cascaded 3D U-Net. 7 clinical landmarks were automatically measured for 96 patients. In AL stage 5, 3D U-Net achieved the highest dice similarity coefficient (DSC) with statistically significant differences (p < 0.01) except from the 2D-3D U-Net ensemble and cascade 3D U-Net. SwinUNETR excelled in 95% Hausdorff distance (HD95) with significant differences (p < 0.01) except from UNETR and 3D U-Net. DSC of aorta and calcification were saturated at stage 1 and 4, whereas thrombus and vessels were continuously improved at stage 5. The segmentation time between the manual and AL-corrected segmentation using the best model (3D U-Net) was reduced to 9.51 ± 1.02, 2.09 ± 1.06, 1.07 ± 1.10, and 1.07 ± 0.97 min for the aorta, thrombus, calcification, and vessels, respectively (p < 0.001). All measurement and tortuosity ratio measured - 1.71 ± 6.53 mm and - 0.15 ± 0.25. We developed an automated workflow with semantic segmentation and measurement, demonstrating its efficiency compared to conventional methods.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Calcinosis , Endovascular Procedures , Thrombosis , Humans , Aortic Aneurysm, Abdominal/diagnostic imaging , Problem-Based Learning , Semantics , Tomography, X-Ray Computed , Image Processing, Computer-Assisted
5.
Arterioscler Thromb Vasc Biol ; 44(5): 1065-1085, 2024 May.
Article in English | MEDLINE | ID: mdl-38572650

ABSTRACT

Blood vessels are subjected to complex biomechanical loads, primarily from pressure-driven blood flow. Abnormal loading associated with vascular grafts, arising from altered hemodynamics or wall mechanics, can cause acute and progressive vascular failure and end-organ dysfunction. Perturbations to mechanobiological stimuli experienced by vascular cells contribute to remodeling of the vascular wall via activation of mechanosensitive signaling pathways and subsequent changes in gene expression and associated turnover of cells and extracellular matrix. In this review, we outline experimental and computational tools used to quantify metrics of biomechanical loading in vascular grafts and highlight those that show potential in predicting graft failure for diverse disease contexts. We include metrics derived from both fluid and solid mechanics that drive feedback loops between mechanobiological processes and changes in the biomechanical state that govern the natural history of vascular grafts. As illustrative examples, we consider application-specific coronary artery bypass grafts, peripheral vascular grafts, and tissue-engineered vascular grafts for congenital heart surgery as each of these involves unique circulatory environments, loading magnitudes, and graft materials.


Subject(s)
Blood Vessel Prosthesis , Hemodynamics , Humans , Animals , Models, Cardiovascular , Prosthesis Failure , Stress, Mechanical , Biomechanical Phenomena , Mechanotransduction, Cellular , Blood Vessel Prosthesis Implantation/adverse effects , Prosthesis Design , Graft Occlusion, Vascular/physiopathology , Graft Occlusion, Vascular/etiology , Vascular Remodeling
6.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Article in English | MEDLINE | ID: mdl-38577923

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Subject(s)
Aortic Dissection , Aortic Valve Insufficiency , Aortic Valve , Blood Vessel Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aortic Dissection/surgery , Aortic Dissection/diagnostic imaging , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/physiopathology , Middle Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Prosthesis Design , Blood Vessel Prosthesis , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm/surgery , Aortic Aneurysm/diagnostic imaging , Aortography
7.
Ann Card Anaesth ; 27(2): 162-164, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38607881

ABSTRACT

ABSTRACT: We report a case of simultaneous transcatheter aortic valve replacement and endovascular aneurysm repair. Our aim was to advocate the role of local and regional anesthesia as a key contributor in maintaining hemodynamic stability and avoiding abrupt blood pressure change. Endovascular combined procedures are gaining popularity for their numerous advantages. Nevertheless, they carry significant risks for their hemodynamic implications. It is imperative to acknowledge the modifications occurring after each correction and act accordingly. Different anesthesia approaches can dramatically influence hemodynamics; among all, we found local and regional anesthesia would better serve this objective.


Subject(s)
Anesthesia, Conduction , Anesthetics , Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Transcatheter Aortic Valve Replacement , Humans , Aortic Aneurysm, Abdominal/surgery
8.
J Cardiothorac Surg ; 19(1): 170, 2024 Apr 02.
Article in English | MEDLINE | ID: mdl-38566230

ABSTRACT

BACKGROUND: Open repair of thoracoabdominal aortic aneurysm (TAAA) was characterized by significant risk of postoperative mortality and morbidity. The aim of this study was to determine the perioperative predictors of early and long-term mortality in patients undergoing open repair of TAAA. Besides, the postoperative outcomes in patients with open repair of TAAA were described. METHODS: This is a single-center retrospective study, and 146 patients with open repair of TAAA from January 4, 2011, to November 22, 2018 was involved. Categorical variables were analyzed by the Chi-square test or Fisher's exact test, and continuous variables were analyzed by the independent sample t-test and the WilCoxon rank-sum test. Multivariate Logistic regression and Cox regression were applied to identify the predictors of 30-day and long-term mortality, respectively. The Kaplan Meier curves were used to illustrate survival with the Log-rank test. RESULTS: The 30-day mortality was 9.59% (n = 14). Older than 50 years, the intraoperative volume of red blood cell (RBC) and epinephrine use were independently associated with postoperative 30-day mortality in open repair of TAAA. Long-term mortality was 17.12% (n = 25) (median of 3.5 years (IQR = 2-5 years) of follow-up). Prior open thoracoabdominal aortic aneurysm (TAAA) repair, aortic cross-clamping (ACC) time, intraoperative volume of RBC and use of epinephrine were independently correlated with long-term mortality. CONCLUSIONS: Identifying perioperative risk factors of early and long-term mortaliy is crucial for surgeons. Intraoperative volume of RBC and use of epinephrine were predictors of both early and long-term mortality. In addition, patients of advanced age, prior open repair of TAAA and prolonged ACC time should be paid more attention.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Aneurysm, Thoracoabdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Aortic Aneurysm, Thoracic/complications , Treatment Outcome , Retrospective Studies , Blood Vessel Prosthesis Implantation/adverse effects , Risk Factors , Epinephrine , Postoperative Complications/etiology , Endovascular Procedures/adverse effects , Risk Assessment
9.
J Cardiothorac Surg ; 19(1): 203, 2024 Apr 13.
Article in English | MEDLINE | ID: mdl-38615049

ABSTRACT

BACKGROUND: Open arch surgery is technically demanding for the surgeon and surgically and biologically invasive for the patient, requiring a variably long period of hypothermic circulatory arrest. CASE PRESENTATION: Here we present a case of an elderly patient with chronic renal failure and multiple splanchnic artery disease successfully treated for a rupturing pseudoaneurysm of the aortic arch with a technique that we developed for particularly frail patients. The procedure includes: triple supra-aortic vessel perfusion; distal thoracic aorta antegrade perfusion; balloon endo-clamping of the descending aorta; and anastomosis of an off-the-shelf hybrid arch prosthesis in Ishimaru zone 0. These maneuvers allowed to maintain an extracorporeal circulation in the phase of distal anastomosis, instead of a period of circulatory arrest, employing just mild hypothermia: technical details are depicted and discussed also in comparison with other methods proposed in the literature. CONCLUSIONS: Being able to take advantage of both open surgery advancements and endovascular methods is the key to cardiovascular surgery success today in front of complex pathologies of the aorta: increasing safety and reducing invasiveness of therapeutic options may progressively extend surgical candidacy to the frailest patients.


Subject(s)
Blood Vessel Prosthesis Implantation , Heart Arrest , Aged , Humans , Aorta, Thoracic/surgery , Aorta , Perfusion
10.
J Cardiothorac Surg ; 19(1): 237, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38627730

ABSTRACT

Redo ascending and aortic arch surgeries following previous cardiac or aortic surgery are associated with high risk of morbidity and mortality due to multiple factors included sternal re-entry injury, extensive aortic arch surgery, emergency aortic surgery, prolonged cardiopulmonary bypass duration, poor heart function, and patients with older age. Therefore, appropriate surgical strategies are important. We report a case of a 72-year-old gentleman with previous surgery of aortic root replacement who presented with acute Type A aortic dissecting aneurysm of ascending and aortic arch complicated with left hemothorax, which was successfully treated by emergency redo aortic surgery with frozen elephant trunk (FET) technique.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Male , Humans , Aged , Aorta, Thoracic/surgery , Blood Vessel Prosthesis , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/methods , Aortic Valve/surgery , Aortic Dissection/surgery , Retrospective Studies , Treatment Outcome , Stents
11.
J Cardiothorac Surg ; 19(1): 226, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38627818

ABSTRACT

BACKGROUND: Sex-related dissimilarities' influence on outcomes following thoracic aortic surgery is poorly understood. Our aim is to examine sex-related disparities in patients undergoing thoracic aortic aneurysm (TAA). METHODS: A total of 455 cases undergoing thoracic aortic aneurysm (TAA) surgery were consecutively enrolled between December 2009 and December 2015 in a Chinese hospital. Primary outcomes, including overall mortality and related risk factors, were evaluated. Cox regression is utilized to recognize the independent risk factor of these consequences. RESULTS: Females, compared to males, had greater indexed aortic diameters and higher aortic transvalvular pressure differences. For the location of aortic aneurysms, females had a higher rate of aortic arch involvement, while males had a higher rate of root involvement. Females underwent less frequent complex proximal aortic operations compared with males (29.5% versus 46.9%; p < 0.001). Women and men both had a lower rate of aortic transvalvular pressure difference and LV volume index 7 days after thoracic aortic surgery. The overall mortality for the women's groups (11%) was suggestively greater compared to 4.9% for the men's groups (p = 0.026). Renal failure and aortic arch involvement were the main risk factors associated with males' survival, while maximum indexed aortic diameter and cross-clamp time were the risk factors associated with females' survival. CONCLUSIONS: The outcome after TAA surgery was less favorable in women with significantly increased overall mortality. It highlights the need to focus on implementing personalized surgery strategies and gender-specific guidelines in treating female patients following TAA surgery.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Thoracic Surgical Procedures , Male , Humans , Female , Retrospective Studies , Aortic Aneurysm, Thoracic/etiology , Aorta, Thoracic/surgery , Risk Factors , Treatment Outcome , Blood Vessel Prosthesis Implantation/adverse effects
12.
J Cardiothorac Surg ; 19(1): 239, 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38632653

ABSTRACT

OBJECTIVES: Aortic pathologies often present with elevated inflammatory biomarkers due to the nature of the disease. Open aortic surgery causes significant trauma to the body due to often mandatory ischemic periods, long cardiopulmonary bypass times and polytransfusion. We aim to determine postoperative trends on inflammation biomarkers for different aortic pathologies and type of surgery in different segments of the aorta. METHODS: Retrospective review of prospectively collected data of 193 consecutive patients who underwent aortic surgery in our centre between 2017 and 2021, grouped according to the type of aortic intervention: (1) Type A aortic dissection (AD) repair with ascending aorta/hemiarch replacement, (2) Aortic root replacement (ARR), (3) Aortic arch + Frozen elephant trunk (FET), (4) Descending thoracic aorta (DTA)/Thoraco-Abdominal aortic repair (TAA). Primary outcomes were daily values of white blood cells (WBC) and C-Reactive Protein (CRP) during the first 15 postoperative days. RESULTS: All groups had a similar inflammatory peak in the first 2-4 days (WBC 12-15 × 109 c/L). AD and FET groups show similar trends with WBC and CRP peaks on days 2 and 10. The ARR group didn't experience the 2nd peak as most patients were already discharged. DTA/TAA patients experienced a more prolonged inflammatory response, reaching a plateau by day 5-10. AD group shows the highest WBC levels and the DTA/TAAA group the highest CRP levels. CRP levels remain elevated (100-200 mg/L) in all groups after 15 postoperative days. CONCLUSIONS: Inflammatory biomarkers show different postoperative trends depending on the clinical presentation and complexity of the aortic procedure performed. Further understanding of the inflammatory response to different aortic pathologies and surgical procedures will permit reduction on the liberal use of antibiotics that this cohort of patients are usually exposed to. An earlier version of the data included in this manuscript was presented as Oral Abstract in the UK Society of Cardiothoracic Surgery Annual meeting in 2021.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Humans , Blood Vessel Prosthesis Implantation/methods , Aorta/surgery , Aorta, Thoracic/surgery , Retrospective Studies , Inflammation , Biomarkers , Aortic Aneurysm, Thoracic/surgery , Treatment Outcome , Blood Vessel Prosthesis
13.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38598445

ABSTRACT

OBJECTIVES: The indications for use, evidence base and experience with the novel noncovered open hybrid surgical stents for acute type A aortic dissection repair for concurrent stabilization of the 'downstream' aorta remains limited. We review the evidence base and the development of these stents. METHODS: Data were collected from Pubmed/Medline literature search to develop and review the evidence base for safety and efficacy of non-covered surgical stents. Existing guidelines for use and developments were reviewed. RESULTS: A single randomized control trial and 4 single-centre studies were included in the review with a total worldwide experience of 241 patients. The deployment was easy and did not add significantly to the primary operation. The mortality and new stroke ranged from 6.3-18.7%. Safe and complete deployment was accomplished in 92-100%. There was no device-related reintervention. There was a significant improvement in malperfusion in over 90% of the cases with varying degrees of remodelling (60-90%) of the downstream aorta. CONCLUSIONS: Open noncovered stent grafts represent a major technical advancement as an adjunct procedure for acute dissection repairs, e.g. hemiarch repair. It has potential for wider use by non-aortic surgeons due to simplicity of technique. Limited safety and efficacy data confirm the device to be safe, feasible and reproducible with potential for wider adoption. However, long-term trial and registry data are required before recommendations for standard use outside of high-volume experienced aortic centres.


Subject(s)
Aortic Dissection , Blood Vessel Prosthesis Implantation , Stents , Humans , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/methods , Endovascular Procedures/adverse effects , Acute Disease , Prosthesis Design , Aortic Aneurysm, Thoracic/surgery , Treatment Outcome , Aortic Aneurysm/surgery
14.
Medicine (Baltimore) ; 103(14): e37731, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38579061

ABSTRACT

RATIONALE: A hostile iliac access route is an important consideration when enforcing endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA). Herein, we report a case of AAA with unilateral external iliac artery occlusion, for which bifurcated EVAR was successfully performed using a single femoral and brachial artery access. PATIENT CONCERNS: A 76-year-old man who had undergone surgery for lung cancer 4.5 years prior was diagnosed AAA by computed tomography (CT). DIAGNOSIS: Two and a half years before presentation, CT revealed an infrarenal 48 mm AAA, which had enlarged to 57 mm by 2 months preoperatively. CT identified occlusion from the right external iliac artery to the right common femoral artery, with no observed ischemic symptoms in his right leg. The right external iliac artery, occluded and atrophied, had a 1 to 2 mm diameter. INTERVENTION: Surgery was commenced with the selection of a Zenith endovascular graft (Cook Medical) with an extended body length. Two Gore Viabahn VBX balloon expandable endoprosthesis (VBX; W.L. Gore & Associate) were delivered from the right axilla as the contralateral leg. OUTCOMES: CT scan on the 2nd day after surgery revealed no endoleaks. LESSONS: While the long-term results remain uncertain, this method may serve as an option for EVAR in patients with unilateral external iliac artery occlusion.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Iliac Aneurysm , Male , Humans , Aged , Aortic Aneurysm, Abdominal/complications , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/methods , Iliac Artery/diagnostic imaging , Iliac Artery/surgery , Axilla/surgery , Leg/surgery , Endovascular Procedures/methods , Stents , Treatment Outcome , Iliac Aneurysm/surgery
15.
Sci Rep ; 14(1): 8057, 2024 04 05.
Article in English | MEDLINE | ID: mdl-38580650

ABSTRACT

The potential of adverse events (AEs) after thoracic endovascular aortic repair (TEVAR) in patients with type B aortic dissection (TBAD) has been reported. To avoid the occurrence of AEs, it is important to recognize high-risk population for prevention in advance. The data of 261 patients with TBAD who received TEVAR between June 2017 and June 2021 at our medical center were retrospectively reviewed. After the implementation of exclusion criteria, 172 patients were finally included, and after 2.8 years (range from 1 day to 5.8 years) of follow up, they were divided into AEs (n = 41) and non-AEs (n = 131) groups. We identified the predictors of AEs, and a prediction model was constructed to calculate the specific risk of postoperative AEs at 1, 2, and 3 years, and to stratify patients into high-risk (n = 78) and low-risk (n = 94) group. The prediction model included seven predictors: Age > 75 years, Lower extremity malperfusion (LEM), NT-proBNP > 330 pg/ml, None distal tear, the ratio between the diameter of the ascending aorta and descending aorta (A/D ratio) > 1.2, the ratio of the area of the false lumen to the total aorta (FL ratio) > 64%, and acute TEVAR, which exhibited excellent predictive accuracy performance and discriminatory ability with C statistic of 82.3% (95% CI 77.3-89.2%). The prediction model was contributed to identify high-risk patients of postoperative AEs, which may serve to achievement of personalized treatment and follow-up plans for patients.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Aged , Endovascular Aneurysm Repair , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/etiology , Retrospective Studies , Endovascular Procedures/adverse effects , Treatment Outcome , Time Factors , Aorta, Thoracic/surgery , Aortic Dissection/surgery , Risk Factors
16.
Kyobu Geka ; 77(3): 163-168, 2024 Mar.
Article in Japanese | MEDLINE | ID: mdl-38465486

ABSTRACT

PURPOSE: We investigated the relationship between aortic remodeling and timing of thoracic endovascular aortic repair( TEVAR) in patients with uncomplicated Stanford type B aortic dissection. METHODS: 29 patients with sub-acute and early chronic uncomplicated Stanford type B aortic dissection underwent TEVAR between February 2019 and August 2022 in our hospital. We retrospectively compared aortic remodeling between 19 patients in the sub-acute( SA) group( 15-90 days from onset) and 10 patients in the early chronic( ECh) group( 91-365 days from onset) using the false luminal area reduction rate using computed tomography imagings. RESULTS: The false lumen area reduction rates at the level of the carina in the SA and ECh groups were 21.9±13.5% and 7.0±21.2% (p=0.04) around 3-8 days after TEVAR, 91.8±13.8% and 62.6±48.4 % (p=0.26) at 6 months, 96.6±7.2% and 68.7±42.5% (p=0.14) at 12 months, and 96.2±10.0% and 79.2±37.6% (p=0.62) at 18 months respectively. There were no significant differences between the two groups regarding any complication. CONCLUSION: Preemptive TEVAR for sub-acute and early chronic uncomplicated Stanford type B aortic dissection resulted in good remodeling and it may provide a good prognosis, especially in the subacute stage.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Endovascular Aneurysm Repair , Retrospective Studies , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Treatment Outcome , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Risk Factors
17.
Kyobu Geka ; 77(2): 101-105, 2024 Feb.
Article in Japanese | MEDLINE | ID: mdl-38459858

ABSTRACT

A 75-year-old woman was diagnosed with type B acute aortic dissection 14 years ago and 3-channeled aortic dissection 7 years ago. She received total arch replacement 6 years ago and descending aortic replacement with double barrel anastomosis technique for distal anastomosis 5 years ago. Computed tomography( CT) revealed giant thyroid tumor and thoracoabdominal aortic aneurysm( 58 mm in diameter). She suffered from back pain during her follow-up period. CT revealed ruptured thoracoabdominal aortic aneurysm. First, the false lumen of descending aorta was closed by thoracic endovascular aortic repair, and then thoracoabdominal aortic replacement was performed uneventfully.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Aneurysm, Thoracoabdominal , Aortic Dissection , Aortic Rupture , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Female , Aged , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Aorta/surgery , Aortic Rupture/diagnostic imaging , Aortic Rupture/surgery , Blood Vessel Prosthesis Implantation/methods , Anastomosis, Surgical , Treatment Outcome
18.
Kyobu Geka ; 77(2): 136-139, 2024 Feb.
Article in Japanese | MEDLINE | ID: mdl-38459863

ABSTRACT

A 67-year-old male was admitted to our hospital for sudden onset chest pain and hoarseness. He underwent 2-debranching thoracic endovascular aortic repair for a ruptured aortic arch aneurysm four years prior. However, computed tomography (CT) revealed an aneurysmal rerupture due to a typeⅠa endoleak. We performed partial arch replacement with uncovered stent removal under intermittent hypothermic circulatory arrest. We needed to be more careful than usual open heart surgery because a non-anatomical bypass procedure was performed. The surgery was successful without any major complications, and the patient was discharged on the 23th postoperative day. Reinterventions post-endovascular repair are sometimes difficult;thus, open surgery could be useful for arch replacement.


Subject(s)
Aneurysm, Aortic Arch , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Male , Humans , Aged , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/surgery , Endovascular Aneurysm Repair , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/complications , Blood Vessel Prosthesis Implantation/adverse effects , Stents/adverse effects , Treatment Outcome , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Blood Vessel Prosthesis/adverse effects , Retrospective Studies
19.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38439540

ABSTRACT

OBJECTIVES: Thoracic endovascular aortic repair (TEVAR) for aortic arch aneurysms is challenging because of anatomical restrictions and the presence of cervical branches. Revascularization of the cervical branch is required when conventional commercial stent grafts are used. TEVAR using fenestrated stent grafts (FSG) often does not require additional procedures to revascularize cervical branches. This study aimed to evaluate the features and initial and midterm outcomes of TEVAR using fenestrated stent grafts. METHODS: From April 2007 to December 2016, 101 consecutive patients underwent TEVAR using fenestrated stent grafts for distal aortic arch aneurysms at a single centre. Technical success, complications, freedom from aneurysm-related death, secondary intervention and aneurysm progression were retrospectively investigated. RESULTS: All the patients underwent TEVAR using fenestrated stent grafts. The 30-day mortality rate was zero. Cerebral infarction, access route problems and spinal cord injury occurred in 4, 3 and 2 patients, respectively. Each type of endoleak was observed in 38 of the 101 patients during the course of the study; 20/38 patients had minor type 1 endoleaks at the time of discharge. The endoleak disappeared in 2 patients and showed no significant change in 8 patients; however, the aneurysm expanded over time in 10 patients. Additional treatment was performed in 8 of the 10 patients with type 1 endoleaks and dilatation of the aneurysm. The rate of freedom from aneurysm-related death during the observation period was 98%. CONCLUSIONS: TEVAR with FSG is a simple procedure, with few complications. Additional treatment has been observed to reduce aneurysm-related deaths, even in patients with endoleaks and enlarged aneurysms. Based on this study, the outcomes of endovascular repair of aortic arch aneurysms using a fenestrated stent graft seem acceptable.


Subject(s)
Aneurysm, Aortic Arch , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Blood Vessel Prosthesis , Endovascular Aneurysm Repair , Endoleak/etiology , Stents , Blood Vessel Prosthesis Implantation/adverse effects , Retrospective Studies , Treatment Outcome , Endovascular Procedures/adverse effects , Prosthesis Design , Time Factors , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/etiology
20.
J Vasc Surg ; 79(3): 457-468.e2, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38453660

ABSTRACT

BACKGROUND: Fenestrated and branched endovascular aortic repair (F/BEVAR) of thoracoabdominal aortic aneurysms (TAAAs) has shown high technical success and low early mortality rates. Aneurysm extent has been reported as a factor affecting outcomes. This study aimed to assess the early and midterm follow-up outcomes of patients managed by F/BEVAR for types I through III TAAAs. METHODS: A single-center retrospective analysis was conducted, including data from consecutive, elective and urgent (symptomatic and ruptured cases), patients treated for types I through III TAAAs, between October 1, 2011, and October 1, 2022, using F/BEVAR. Degenerative and postdissection TAAAs were included. Patients received prophylactic cerebrospinal fluid drainage (CSFD), except those under therapeutic anticoagulation, those who were hemodynamically unstable, or those with failed CSFD application. When an initial thoracic endovascular aortic repair was performed, as part of a staged procedure, no CSFD was used. Later stages and nonstaged procedures were performed under CSFD. Thirty-day mortality and major adverse events (MAEs) were analyzed. Kaplan-Meier estimates were used for follow-up outcomes. RESULTS: F/BEVAR for types I through III TAAAs was performed in 209 patients (56.9% males; mean age, 69.6 ± 3.2 years; mean aneurysm diameter, 65.2 ± 6.2 mm); 29.2% type I, 57.9% type II, and 12.9% type III. Urgent repair was performed in 26.7% of patients (56 cases; 23 ruptured and 33 symptomatic cases) and 153 were treated electively. Thirty-two patients (15.3%) were classified as American Society of Anesthesiologists (ASA) class IV. CSFD was used in 91% and staged thoracic endovascular aortic repair was performed in 51.2% of patients. Technical success was 93.8% (96.7% in elective vs 94.6% in urgent cases; P = .92). Thirty-day mortality was 11.0% (4.6% in elective vs 28.5% in urgent cases; P < .001) and MAEs were recorded in 17.2% of cases (7.8% in elective vs 42.8% in urgent cases; P < .001). Spinal cord ischemia rate was 20.5% (17.6% in elective vs 28.7% in urgent cases; P = .08), whereas 2.9% of patients presented paraplegia (1.3% in elective and 7.1% in urgent cases; P = .03). The mean follow-up was 16 ± 5 months. Survival was 75.0% (standard error, 4.0%) and freedom from reintervention was 73.3% (standard error, 4.4%) at 36 months. ASA IV and urgent repair were detected as independent factors related to early mortality and MAE, whereas ruptured aneurysm status was related to spinal cord ischemia evolution. CONCLUSIONS: Endovascular repair for types I through III TAAAs provides encouraging early outcomes in terms of mortality, MAE, and paraplegia, especially in an elective setting. Setting of repair and baseline ASA score should be taken into consideration during decision-making.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Spinal Cord Ischemia , Male , Humans , Aged , Female , Endovascular Aneurysm Repair , Blood Vessel Prosthesis , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Retrospective Studies , Risk Factors , Treatment Outcome , Endovascular Procedures/adverse effects , Spinal Cord Ischemia/etiology , Paraplegia/etiology
SELECTION OF CITATIONS
SEARCH DETAIL
...